COLUMN COMPONENTS
Column Components are widely used in applications such as distillation, absorption, rectifications etc. These are the essential part of Engineered Systems. Below given are some of the wide ranges of Column Components available.
COLUMN SECTION
We manufacture wide range of Column Sections with different types of Column Packing. We supply packing retainers, Liquid re-distributers etc, as well. |
| COLUMN SECTION |
DN |
L |
H |
RR Packings |
Cat. Ref |
80 |
1000 |
835 |
FC 8 |
CS 80/1000 |
100 |
1000 |
840 |
FC 10 |
CS 100/1000 |
150 |
1000 |
830 |
FC 15 |
CS 150/1000 |
225 |
1000 |
830 |
FC 20 |
CS 225/1000 |
300 |
1000 |
825 |
FC 25 |
CS 300/1000 |
|
|
|
|
| |
COLUMN ADAPTORS
We manufacture two types of Column Adaptors – Round top type & Flat top type. Depending on the particular duty and space availability, any of the above can be selected. Column Adaptors are mainly used as top component in Rectification and Absorption Column. |
| COLUMN ADAPTORS |
DN |
DN1 |
DN2 |
L |
L1 |
L2 |
Cat.Ref |
80 |
40 |
25 |
200 |
150 |
75 |
CA 80/40/25 |
100 |
50 |
25 |
250 |
125 |
125 |
CA 100/50/25 |
150 |
50 |
25 |
250 |
125 |
150 |
CA 150/50/25 |
150 |
80 |
25 |
300 |
150 |
150 |
CA 150/80/25 |
225 |
50 |
40 |
300 |
150 |
175 |
CA 225/50/40 |
225 |
80 |
40 |
300 |
150 |
200 |
CA 225/80/40 |
225 |
100 |
40 |
300 |
150 |
200 |
CA 225/100/40 |
225 |
150 |
40 |
400 |
175 |
250 |
CA 225/150/40 |
300 |
50 |
40 |
300 |
150 |
225 |
CA 300/50/40 |
300 |
80 |
40 |
350 |
150 |
250 |
CA 300/80/40 |
300 |
100 |
40 |
400 |
175 |
250 |
CA 300/100/40 |
300 |
150 |
40 |
450 |
225 |
250 |
CA 300/150/40 |
|
|
 |
|
| |
REFLUX SEPARATOR
Reflux Separator is used control the reflux ratio in rectification column. We manufacture two types of Reflux Separators – Manually operated Reflux Separator & Electromagnetically operated Reflux Separators.
In manually operated Reflux Separator, the reflux is adjusted by means of a manually operated valve on the distillate outlet connection. When the valve is fully open, it is Nil Reflux. By regulating the valve, the reflux ratio can be continuously adjusted to Total Reflux.
When the valve is fully closed, it is Total Reflux.
Electro magnetically operated Reflux separators are used to keep a specific and reproducible Reflux ratio. It uses an electromagnetically operated swinging funnel mechanism to separate the reflux.
|
| REFLUX SEPARATOR |
DN |
DN1 |
L |
L1 |
Cat.Ref |
80 |
25 |
200 |
115 |
RDA 80 |
100 |
25 |
250 |
145 |
RDA 100 |
150 |
25 |
250 |
145 |
RDA 150 |
225 |
25 |
375 |
165 |
RDA 225 |
300 |
25 |
375 |
165 |
RDA 30 |
|
|

|
|
| |
LIQUID SEAL
Liquid seals are used to prevent the passage of vapours to restricted areas. A drain valve can be fitted so that Liquid Seal can be fully drained. |
| LIQUID SEAL |
DN |
DN1 |
L |
L1 |
Cat.Ref |
25 |
25 |
160 |
205 |
LS 25 |
40 |
25 |
315 |
305 |
LS 40 |
|
|
|
|
|
|
| |
|
|